Comparison of two column agglutination tests for red blood cell antibody testing

Sawierucha, Jonas and Posset, Marion and Haehnel, Viola and Johnson, Christian L. and Hutchinson, James A. and Ahrens, Norbert (2018) Comparison of two column agglutination tests for red blood cell antibody testing. PLOS ONE, 13 (12): e0210099. ISSN 1932-6203,

Full text not available from this repository. (Request a copy)

Abstract

Background Several sensitive methods are available for red blood cell (RBC) antibody screening. Among these, gel and glass card systems have demonstrated comparably good performance in retrospective studies and are widely used in routine patient diagnostics, but their performance in prospective studies has not been sufficiently characterised. Patients and methods Gel card (Bio-Rad DiaMed) and glass bead-based (Ortho Clinical Diagnostics) column agglutination technologies were used to screen for antibodies prospectively (group A) and for antibody identification in stored and fresh samples known to contain RBC antibodies retrospectively (group B). Untreated reagent RBCs and either papain-treated (Bio-Rad) or ficin-treated panel C cells (Ortho) were used for antibody identification. Results RBC-reactive antibodies were detected in 22 of 1000 group A samples, three of which tested positive only by gel card agglutination, and four only by glass bead agglutination (including one false positive each). Group B comprised 202 sera with known antibodies: 33 of these samples contained 36 antibodies detected only by gel card agglutination, whereas 9 samples contained antibodies detectable only by glass bead-based agglutination. Discrepancies mostly involved weak antibodies reactive by enzyme only. Two sera contained antibody mixtures that neither system detected completely. Of note, in antibody differentiation batches one and two, anti-Lu a was reactive in 7 of 7 and 1 of 8 samples, respectively. Conclusion Both column agglutination tests for red cell antibodies had equal sensitivity and specificity with unstored samples. In stored samples, weak and enzyme-only antibodies were more frequently detected with the gel card system.

Item Type: Article
Uncontrolled Keywords: SYSTEMS; GEL; AUTOANTIBODIES; ALLOANTIBODIES; PERFORMANCE; PERSISTENCE;
Subjects: 600 Technology > 610 Medical sciences Medicine
Divisions: Medicine > Lehrstuhl für Chirurgie
Medicine > Lehrstuhl für Klinische Chemie und Laboratoriumsmedizin
Depositing User: Dr. Gernot Deinzer
Date Deposited: 02 Oct 2019 10:21
Last Modified: 02 Oct 2019 10:21
URI: https://pred.uni-regensburg.de/id/eprint/13327

Actions (login required)

View Item View Item