Apparent diffusion coefficient measurements of the pancreas, pancreas carcinoma, and mass-forming focal pancreatitis

Wiggermann, Philipp and Gruetzmann, Robert and Weissenboeck, Angelika and Kamusella, Peter and Dittert, Dag-Daniel and Stroszczynski, Christian (2012) Apparent diffusion coefficient measurements of the pancreas, pancreas carcinoma, and mass-forming focal pancreatitis. ACTA RADIOLOGICA, 53 (2). pp. 135-139. ISSN 0284-1851,

Full text not available from this repository. (Request a copy)

Abstract

Background: Mass-forming focal pancreatitis (FP) may mimic pancreatic cancer (PC) on magnetic resonance (MR) imaging, and the preoperative differential diagnosis is often difficult. Recently, the usefulness of diffusion-weighted imaging (DWI) in the diagnosis of pancreatic cancer has been reported in several studies. Purpose: To investigate if apparent diffusion coefficient (ADC) measurements based on diffusion-weighted echo-planar imaging (DW-EPI) may distinguish between normal pancreas parenchyma, mass-forming focal pancreatitis, and pancreas carcinoma. Material and Methods: MRI was performed on 64 patients: 24 with pancreas carcinoma (PC), 20 with mass-forming focal pancreatitis (FP), three patients with other focal pancreatic disease as well as 17 controls without any known pancreatic disease. Diffusion-weighted sequence with ADC maps and T2-weighted sequence for anatomical information was performed. Apparent diffusion coefficient (ADC) maps were automatically created and analyzed using a dedicated user interface. In the group with pancreas disease the abnormal parenchyma was detected by using T1- and T2-weighted images and the region of interest (ROI) was transferred exactly to the ADC map and the coefficients were registered. In the control group the ROI was set to the head of the pancreas followed by a similar registration of the ADCs. Results: ADC values for mass-forming FP and PC differed significantly from ADC values for normal pancreas parenchyma (P = 0.001 / P = 0.002). Mean ADC values for mass-forming FP were 0.69 +/- 0.18 x 10(-3) mm(2)/s. ADC values for PC were 0.78 +/- 0.11 x 10(-)3 mm(2)/s, compared to ADC values of 0.17 +/- 0.06 x 10(-3) mm(2)/s in the control group. However there was no significant difference in ADCs between PC and mass-forming FP (P = 0.15). Conclusion: ADC measurements clearly differentiated between normal pancreatic tissue and abnormal pancreas parenchyma (PC and mass-forming FP). However there is an overlap in values of PC and mass-forming FP, with the consequent problem of their correct identification.

Item Type: Article
Uncontrolled Keywords: WEIGHTED IMAGING DWI; HEALTHY-VOLUNTEERS; LESIONS; CANCER; MRI; EXPERIENCE; ABDOMEN; LIVER; DIFFERENTIATION; MRI; diffusion-weighted imaging; apparent diffusion coefficient; abdominal imaging; pancreas
Subjects: 600 Technology > 610 Medical sciences Medicine
Divisions: Medicine > Lehrstuhl für Röntgendiagnostik
Depositing User: Dr. Gernot Deinzer
Date Deposited: 19 May 2020 05:00
Last Modified: 19 May 2020 05:00
URI: https://pred.uni-regensburg.de/id/eprint/19138

Actions (login required)

View Item View Item