Is the rotation of the femural head a potential initiation for cutting out? A theoretical and experimental approach

Lenich, Andreas and Bachmeier, Samuel and Prantl, Lukas and Nerlich, Michael and Hammer, Jochen and Mayr, Edgar and Al-Munajjed, Amir Andreas and Fuechtmeier, Bernd (2011) Is the rotation of the femural head a potential initiation for cutting out? A theoretical and experimental approach. BMC MUSCULOSKELETAL DISORDERS, 12: 79. ISSN 1471-2474,

Full text not available from this repository. (Request a copy)

Abstract

Background: Since cut-out still remains one of the major clinical challenges in the field of osteoporotic proximal femur fractures, remarkable developments have been made in improving treatment concepts. However, the mechanics of these complications have not been fully understood. We hypothesize using the experimental data and a theoretical model that a previous rotation of the femoral head due to de-central implant positioning can initiate a cut-out. Methods: In this investigation we analysed our experimental data using two common screws (DHS/Gamma 3) and helical blades (PFN A/TFN) for the fixation of femur fractures in a simple theoretical model applying typical gait pattern on de-central positioned implants. In previous tests during a forced implant rotation by a biomechanical testing machine in a human femoral head the two screws showed failure symptoms (2-6Nm) at the same magnitude as torques acting in the hip during daily activities with de-central implant positioning, while the helical blades showed a better stability (10-20Nm). To calculate the torque of the head around the implant only the force and the leverarm is needed (N [Nm] = F [N] * x [m]). The force F is a product of the mass M [kg] multiplied by the acceleration g [m/s(2)]. The leverarm is the distance between the center of the head of femur and the implant center on a horizontal line. Results: Using 50% of 75 kg body weight a torque of 0.37Nm for the 1 mm decentralized position and 1.1Nm for the 3 mm decentralized position of the implant was calculated. At 250% BW, appropriate to a normal step, torques of 1.8Nm (1 mm) and 5.5Nm (3 mm) have been calculated. Comparing of the experimental and theoretical results shows that both screws fail in the same magnitude as torques occur in a more than 3 mm de-central positioned implant. Conclusion: We conclude the center-center position in the head of femur of any kind of lag screw or blade is to be achieved to minimize rotation of the femoral head and to prevent further mechanical complications.

Item Type: Article
Uncontrolled Keywords: TIP-APEX DISTANCE; TROCHANTERIC FRACTURES; HELICAL BLADE; HIP-JOINT; FIXATION; FAILURE; SCREW; NAIL; proximal femur fractures osteosynthesis; center-center-position; cutting out
Subjects: 600 Technology > 610 Medical sciences Medicine
Divisions: Medicine > Lehrstuhl für Unfallchirurgie