Ultrahochfrequenz-Sonografie bei der Evaluation der Hautatrophie bei Patienten mit systemischer Langzeit-Glukokortikoid-Therapie in einem rheumatologischen Tertiärzentrum = Performance of ultra-high-frequency ultrasound in the evaluation of skin atrophy in patients with long-term oral glucocorticoid therapy in a tertiary rheumatology center

Turowski, Timo and Fleck, Martin and Ehrenstein, Boris and Hartung, Wolfgang and Günther, Florian (2025) Ultrahochfrequenz-Sonografie bei der Evaluation der Hautatrophie bei Patienten mit systemischer Langzeit-Glukokortikoid-Therapie in einem rheumatologischen Tertiärzentrum = Performance of ultra-high-frequency ultrasound in the evaluation of skin atrophy in patients with long-term oral glucocorticoid therapy in a tertiary rheumatology center. ULTRASCHALL IN DER MEDIZIN, 46 (06). pp. 578-584. ISSN 0172-4614, 1438-8782

Full text not available from this repository. (Request a copy)

Abstract

Purpose Ultra-high-frequency ultrasound (UHF-US) allows visualization of the epidermis, dermis, and subcutis and precise measurement of skin thickness. The aim of this study was to assess the performance and interobserver reliability of UHF-US for measuring skin thickness in patients with long-term systemic glucocorticoid (GC) therapy compared to patients without GC therapy or treated for a shorter period. Materials and Methods 156 patients with known or suspected inflammatory rheumatic diseases underwent US evaluation for skin thickness by 3 experts in 3 anatomical sites (hand, distal, and proximal forearm). 87 patients were classified as "frequent users" who had received continuous oral GCs for at least one year or at least 3 years with various interruptions. 69 patients without any oral GC therapy in the past or treated for a shorter period were classified as "non-frequent users". Results UHF-US allowed a precise measurement of skin thickness. Skin thickness at all 3 anatomical sites was significantly decreased in "frequent users" of GCs compared to "non-frequent users" (distal and proximal forearm: p < 0.001; hand: p < 0.05). At all 3 anatomical sites, skin thickness was decreased in patients with clinically assessed parchment-like skin compared to patients without parchment-like skin (distal and proximal forearm: p < 0.001; hand: p < 0.05). Interobserver variability was excellent [hand intraclass correlation coefficient (ICC) = 0.99; proximal forearm ICC = 0.85; distal forearm ICC = 0.84]. Conclusion These data support the idea of UHF-US as an objective and reliable imaging tool for monitoring skin atrophy as adverse effects of GC therapy.

Item Type: Article
Uncontrolled Keywords: EULAR RECOMMENDATIONS; CARDIOVASCULAR EVENTS; SYSTEMIC-SCLEROSIS; ARTHRITIS; THICKNESS; DISEASES; RISK
Subjects: 600 Technology > 610 Medical sciences Medicine
Divisions: Medicine > Lehrstuhl für Innere Medizin I
Depositing User: Dr. Gernot Deinzer
Date Deposited: 05 Nov 2026 10:52
Last Modified: 05 Nov 2026 10:52
URI: https://pred.uni-regensburg.de/id/eprint/66801

Actions (login required)

View Item View Item