Scheiter, Alexander and Mattern, Sven and Gassenmaier, Verena and Schildhaus, Hans-Ulrich and Christgen, Matthias and Kreipe, Hans and Herbst, Hermann and Lambert, Bettina and Sauter, Guido and Lennartz, Maximilian and Jöhrens, Korinna and Sperling, Florian and Soleiman, Afschin and Erber, Ramona and Singer, Stephan and Staebler, Annette and Utpatel, Kirsten (2025) Results of the First Folate Receptor Alpha Testing Trial by the German Quality Assurance Initiative in Pathology (QuIP®). CANCERS, 17 (22): 3703. ISSN 2072-6694
Full text not available from this repository. (Request a copy)Abstract
Background: Folate receptor alpha (FR alpha) is a glycosylphosphatidylinositol-anchored membrane protein encoded by the FOLR1 gene. Its overexpression in various cancers, including ovarian carcinoma, makes it a promising target for antibody-drug conjugates (ADC). Mirvetuximab soravtansine-gynx, an FR alpha-targeting ADC, has been approved by the FDA and EMA for the treatment of FR alpha-positive, platinum-resistant ovarian cancer. In the United States, patient selection is tied to the VENTANA FOLR1 (FOLR1-2.1) RxDx Assay, an immunohistochemical (IHC) test that identifies tumors with >= 75% moderate-to-strong membrane staining. However, in the European Union, no specific IHC test is mandated, and alternative antibodies are frequently used in routine pathology, necessitating validation of their diagnostic performance. Methods and Results: We report the results of the first interlaboratory proficiency trial on FR alpha testing conducted by the German Quality Assurance Initiative in Pathology (QuIP (R)). Sixty-eight pathology institutes participated across internal and open trials using a variety of antibodies and staining platforms. The VENTANA FOLR1 RxDx Assay demonstrated the highest reliability, with 83% of participating laboratories achieving a successful result. In contrast, alternative clones such as BN3.2 (Leica/Novocastra) and EPR20277 (Abcam) showed substantially weaker staining intensity, lower concordance with reference values, and success rates of only 22-25%, while other antibodies failed entirely. Problem analysis revealed that failures with the VENTANA FOLR1 (FOLR1-2.1) RxDx Assay were mainly due to interpretative challenges, whereas weak staining was the predominant issue with alternative clones. Participation in a preparatory online seminar improved pass rates, underscoring the importance of training. Conclusions: These findings highlight the critical importance of standardized, validated assays for FR alpha detection to ensure accurate patient selection for targeted therapies. The study emphasizes the need for further optimization of alternative antibodies before clinical implementation.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | MIRVETUXIMAB SORAVTANSINE; IMMUNOHISTOCHEMISTRY; EXPRESSION; folate receptor alpha (FR alpha); immunohistochemistry (IHC); antibody-drug conjugates (ADC); proficiency testing; biomarker validation |
| Subjects: | 600 Technology > 610 Medical sciences Medicine |
| Divisions: | Medicine > Lehrstuhl für Pathologie |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 10 Nov 2026 06:31 |
| Last Modified: | 10 Nov 2026 06:31 |
| URI: | https://pred.uni-regensburg.de/id/eprint/66854 |
Actions (login required)
![]() |
View Item |

