Kääb, Max J. and Reuther, Falk and Joudet, Thierry and Kohut, Georges and Irlenbusch, Ulrich (2025) Long-term clinical and radiographic outcomes after inverted-bearing reverse total shoulder arthroplasty: a multicenter study with the Affinis Inverse prosthesis. JOURNAL OF SHOULDER AND ELBOW SURGERY, 34 (12). e1182-e1189. ISSN 1058-2746, 1532-6500
Full text not available from this repository. (Request a copy)Abstract
Background: Inverted-bearing reverse total shoulder arthroplasty (IB-rTSA) prostheses feature a polyethylene glenosphere and a metallic or ceramic humeral liner. Although midterm clinical results are promising, long-term clinical data with IB-rTSA are limited. Therefore, we evaluated the long-term clinical and radiographic outcomes of IB-rTSA in a variety of shoulder pathologies. Additionally, we reported the type and rate of scapular notching and assessed its effect on clinical results. Finally, we recorded implant survival and complication rates. Methods: In this prospective, multicenter, observational study, patients with different shoulder pathologies underwent IB-rTSA with the Affinis Inverse prosthesis. We recorded clinical and functional scores, active range of motion, pain, radiolucent lines, and the type and rate of scapular notching. All complications were documented, and prosthesis survival rates were calculated. Results: We included 318 patients (335 shoulders) with IB-rTSA. The final clinical and radiographic analysis involved 175 patients (183 shoulders), examined at a median of 120.7 months (range, 84.1-172.4 months). At final follow-up, clinical and functional scores, active range of motion, and pain improved significantly from preoperative values (P < .001). Additionally, improvements at the final follow-up in clinical scores and pain substantially exceeded the corresponding minimal clinically important difference determined for rTSA. The type of scapular notching was strikingly different from that observed with conventional rTSA prostheses, and no grade 4 scapular notching was seen. We found scapular notching in 63 (35.8%) shoulders, and the presence of scapular notching did not affect long-term clinical outcomes as well as complication and prosthesis survival rates. The overall prosthesis survival for any revision was 95.7% at 14 years. Conclusions: IB-rTSA with the Affinis Inverse prosthesis resulted in excellent long-term clinical scores and radiographic outcomes, low scapular notching rates, and high prosthesis survival rates in patients with a range of shoulder pathologies. Overall, patients undergoing IB-rTSA can expect good and stable long-term clinical outcomes with low complication and revision rates, making it a viable choice for different shoulder pathologies. (c) 2025 The Author(s). Published by Elsevier Inc. on behalf of Journal of Shoulder and Elbow Surgery Board of Trustees. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | IMPORTANT DIFFERENCE; FOLLOW-UP; BASEPLATE; CONSTANT; SCORE; Reverse total shoulder arthroplasty; inverted-bearing rTSA; IB-rTSA; scapular notching; clinical outcomes; long-term prosthesis survival; complications; PE-induced osteolysis |
| Subjects: | 600 Technology > 610 Medical sciences Medicine |
| Divisions: | Medicine > Lehrstuhl für Unfallchirurgie |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 23 Nov 2026 06:44 |
| Last Modified: | 23 Nov 2026 06:44 |
| URI: | https://pred.uni-regensburg.de/id/eprint/67115 |
Actions (login required)
![]() |
View Item |