Development and First Results of Fast and Cost-Effective Examination Methods for an Ophthalmological Screening within the National Cohort

Leitritz, M. A. and Hense, H. -W. and Schiefer, U. and Nagel, M. and Greiser, H. and Linseisen, J. and Heid, I. and Fischer, B. and Thierry, S. and Bartz-Schmidt, K. U. and Ueffing, M. (2013) Development and First Results of Fast and Cost-Effective Examination Methods for an Ophthalmological Screening within the National Cohort. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 230 (12). pp. 1238-1246. ISSN 0023-2165, 1439-3999

Full text not available from this repository. (Request a copy)

Abstract

Background: For an implemented ophthalmological screening within a German long-term cohort study (National Cohort) simple and effective methods for an examination of visual acuity and for non-mydriatic retina photografies should be evaluated. Furthermore standard operating-procedures (SOP) should be developed. Methods: In the years 2011 and 2012 pinhole visual acuity measurements and automated retina photographies (DRS, CenterVue S.p.a., Padua, Italy) were made at three different epidemiological study centers within Germany. Furthermore, anterior segment images were taken by the camera. Standard operating procedures (SOP) regarding the ophthalmological screening were developed and evaluated within the study. The main question was whether it is possible to implement the screening methods within the National Cohort. Further main outcomes were quality and interpretability of the taken images. Results: 457 subjects (914 eyes) were examined within the investigation. Median VA was 0.8 for right and left eyes (p>0.42). Image quality of the photographies was good in 491 cases (54%), fair in 239 cases (26%) and bad in 179 cases (20%). The usability of the images was without limitations in 686 cases (75%), limited in 152 cases (17%) and not given in 71 cases (8%). Increasing age of the subjects was slightly correlated with decreasing image quality (r=0.26) and decreasing image usability (r=0.2). Anterior segment photographies were usable in 176 eyes (56%). Conclusion: The developed screening method fulfilled the specifications of the National Cohort. The used pinhole visual acuity examination was fast and cheap. Image quality and usability of the retina photographies could be improved with prolonged pupil recovery times. The quality of the anterior segment images could not fulfill the expectations and were taken out of the further examinations of the ophthalmological screening. The written SOP showed good acceptance within the investigators daily routine. The ophthalmological screening within the National Cohort generates information (e.g., pathologies of the vessels or of the retina) which are useful not only from an ophthalmological point of view.

Item Type: Article
Uncontrolled Keywords: QUALITY; HEALTH; screening; National Cohort; non-myd fundus photography; visual acuity
Subjects: 500 Science > 570 Life sciences
Divisions: Medicine > Institut für Epidemiologie und Präventivmedizin > Lehrstuhl für Genetische Epidemiologie
Depositing User: Dr. Gernot Deinzer
Date Deposited: 24 Mar 2020 13:13
Last Modified: 24 Mar 2020 13:13
URI: https://pred.uni-regensburg.de/id/eprint/15576

Actions (login required)

View Item View Item