Frohnmeyer, Esther and Tuschel, Nadine and Sitz, Tobias and Hermann, Cornelia and Dahl, Gregor T. and Schulz, Florian and Baeumner, Antje J. and Fischer, Markus (2019) Aptamer lateral flow assays for rapid and sensitive detection of cholera toxin. ANALYST, 144 (5). pp. 1840-1849. ISSN 0003-2654, 1364-5528
Full text not available from this repository. (Request a copy)Abstract
Aptamers are envisioned to serve as powerful synthetic substitutes to antibodies in a variety of bioanalytical assay formats. However, lateral flow assays (LFAs) remain dominated by antibody-based strategies. In this study, a LFA for the detection of cholera toxin as a model analyte is developed and optimized using a synthetic aptamer and a naturally occurring receptor as biorecognition elements and directly compared with solely aptamer and aptamer and antibody-based alternative approaches. The aptamer (CT916) recently selected by our group, GM1 receptors and an anti-cholera toxin antibody were evaluated. Relying solely on molecules that can easily be synthesized while aiming for high sensitivity, we applied a novel combination of capture aptamer and GM1 cell receptor-labeled liposomes for cholera toxin detection, achieving a limit of detection (LOD) of 2 ng ml(-1) (3 sigma)/10 ng ml(-1) (visual) in approximate to 15 min. To put our novel aptasensor into perspective, we developed a competitive lateral flow assay, exploiting the competition of cholera toxin in solution with immobilized cholera toxin for binding of aptamer-coated gold nanoparticles (AuNPs) (LOD = 51 ng ml(-1) (3 sigma)/100 ng ml(-1) (visual), assay time approximate to 10 min). As dual simultaneously binding aptamers were not available, we designed aptamer antibody pair-based lateral flow assays using aptamer-coated AuNPs which yielded a LOD of 5 ng ml(-1) (by the 3 sigma rule)/10 ng ml(-1) (visual) in a 10 min assay and an even better LOD of 0.6 ng ml(-1) (3 sigma)/1 ng ml(-1) (visual), with an approximate to 20 min total assay time. All set-ups are highly specific and provide an excellent alternative for cholera toxin detection in places where professional knowledge and sophisticated equipment are not readily available and cost efficient, simple, and rapid tests are needed, while the combination of GM1 cell receptor-labeled liposomes and aptamers is clearly the most promising.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | LINKED-IMMUNOSORBENT-ASSAY; ULTRASENSITIVE DETECTION; GOLD NANOPARTICLES; BINDING; ANTIBODIES; STABILITY; LIPOSOMES; DIAGNOSIS; SENSOR; STRIP; |
| Subjects: | 500 Science > 540 Chemistry & allied sciences |
| Divisions: | Chemistry and Pharmacy > Institut für Analytische Chemie, Chemo- und Biosensorik > Chemo- und Biosensorik (Prof. Antje J. Bäumner, formerly Prof. Wolfbeis) |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 21 Apr 2020 05:30 |
| Last Modified: | 21 Apr 2020 05:30 |
| URI: | https://pred.uni-regensburg.de/id/eprint/27374 |
Actions (login required)
![]() |
View Item |

