Fredersdorf, Sabine and Weber, Stefan and Jilek, Clemens and Heinicke, Norbert and Von Bary, Christian and Jungbauer, Carsten and Riegger, Guenter A. and Hamer, Okka W. and Jeron, Andreas (2009) Safe and Rapid Isolation of Pulmonary Veins Using a Novel Circular Ablation Catheter and Duty-Cycled RF Generator. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 20 (10). pp. 1097-1101. ISSN 1045-3873, 1540-8167

Full text not available from this repository. (Request a copy)

Abstract

Safe and Rapid Isolation of Pulmonary Veins. Background: Ablation of atrial fibrillation (AF) has been one of the most difficult and time-consuming electrophysiological procedures. Due to the rapidly increasing demand for ablation procedures, technical advances would be helpful to reduce complexity and procedure time in AF ablation. Therefore, we investigated the feasibility of a single-catheter technique for pulmonary vein (PV) isolation utilizing a decapolar catheter combined with a duty-cycled, unipolar-bipolar radiofrequency (RF) generator. Methods: AF mapping and ablation was performed in 21 consecutive patients (mean age 59 +/- 12 years, 9 males) with paroxysmal AF (n = 17) and persistent AF (n = 4). The ablation catheter was forwarded to the LA via single-transseptal puncture. All electrodes were energized in 2 to 5 applications per vein, followed by segmental RF applications, as needed, to achieve electrical isolation. To assess left atrial anatomy for purposes of catheter manipulation, and later evaluate the possibility of asymptomatic PV-stenosis, CT or MR imaging was performed both prior to ablation and at 6-month follow-up. Results: Isolation could be achieved in 85/86 veins (99%). Procedure time for ablation was 81 +/- 13 minutes, and fluoroscopy time was 30 +/- 11 minutes. There were no procedural complications. Success rate at 6 months was 86% (18/21). MR or CT imaging excluded asymptomatic PV-stenosis. Conclusion: Mapping and ablation of PVs can be performed in a safe and efficient manner using a single-catheter technique, with short procedure times and minimal learning curve. Thus, this system may be of high interest not only for high volume but all centers performing AF ablation. (J Cardiovasc Electrophysiol, Vol. 20, pp. 1097-1101, October 2009)

Item Type: Article
Uncontrolled Keywords: PERSISTENT ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; SECULAR TRENDS; ONSET; PREVALENCE; atrial fibrillation; catheter ablation; electrophysiology; mapping; pulmonary vein isolation
Subjects: 600 Technology > 610 Medical sciences Medicine
Divisions: Medicine > Lehrstuhl für Innere Medizin II
Medicine > Lehrstuhl für Röntgendiagnostik
Depositing User: Dr. Gernot Deinzer
Date Deposited: 04 Sep 2020 06:49
Last Modified: 04 Sep 2020 06:49
URI: https://pred.uni-regensburg.de/id/eprint/28353

Actions (login required)

View Item View Item