Loher, Hans and Behr, M. and Hintereder, U. and Rosentritt, M. and Handel, G. (2009) The impact of cement mixing and storage errors on the risk of failure of glass-ceramic crowns. CLINICAL ORAL INVESTIGATIONS, 13 (2). pp. 217-222. ISSN 1432-6981, 1436-3771
Full text not available from this repository. (Request a copy)Abstract
This study evaluated the impact of different mixing ratios and wrongly stored blends of dual-curing composite cements on Empress2 glass-ceramic crowns by means of a flexural strength test and a fracture resistance test. Thermally damaged blends and fresh blends were mixed using different mixing ratios of dual-curing Panavia F and Variolink II composite cement (2:1; 1:1; 1:1.5; 1:1.75; base/catalyst). Sixteen groups of rectangular beams of both cements (two blends, four ratios, chemical-curing, light-curing) were constructed. Their flexural strength was determined in a three-point bending test. Furthermore, 64 Empress2 all-ceramic crowns were luted onto human molars, again using fresh and thermally damaged blends as well as different mixing ratios of the luting agents. After aging, fracture resistance was investigated. The flexural strength of dual-curing composite cements was influenced to a statistically significant extent by mixing ratios and storage conditions. In particular, the chemical curing mode of these cements was affected by the thermal damage of the blends. However, this study could not demonstrate a significant impact on the fracture resistance of Empress2 glass-ceramic crowns when different mixing ratios or wrongly stored cements were used. Dual-curing composite luting agents seem to tolerate a wide range of mixing errors, but their chemical curing mode may be affected by storage errors.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | CLINICAL-PERFORMANCE; POWDER/LIQUID RATIO; RESIN CEMENT; CAST GOLD; STRENGTH; LOAD; Glass-ceramic crown; Mixing error; Composite cements; Dark curing; Storage |
| Subjects: | 600 Technology > 610 Medical sciences Medicine |
| Divisions: | Medicine > Lehrstuhl für Zahnärztliche Prothetik |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 14 Sep 2020 09:45 |
| Last Modified: | 14 Sep 2020 09:45 |
| URI: | https://pred.uni-regensburg.de/id/eprint/28851 |
Actions (login required)
![]() |
View Item |