Warnat, Jan and Liebsch, Gregor and Stoerr, Eva-Maria and Brawanski, Lexander and Woertgen, Chris (2008) Simultaneous imaging of cortical partial oxygen pressure and anatomic structures using a transparent optical sensor foil. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 20 (2). pp. 116-123. ISSN 0898-4921,

Full text not available from this repository. (Request a copy)

Abstract

Background/Purpose: Reliable information of cerebral oxygenation is-besides the monitoring of the intracranial pressure-of eminent interest when treating patients with brain injuries. In this study, we introduce a new, fast, and sensitive method capable of determining the cortical partial oxygen pressure on the surface of the cortex using a special sensor foil. Methods: The introduced method exploits the O-2-dependent phosphorescence of a thin sensor foil, which is excited by a short light-emitting diode flash. The optical signal is registered by a charge-coupled device camera and analyzed with PC-based software. The adequacy of this method was tested in 10 animals. The sensor device was placed directly over the cortex after craniotomy and removal of the dura. Arterial oxygen pressure was systematically varied by modifying the ventilation gas mixture. A total of 225 measurements were performed within 4 regions of interest. Results: Obtained results were sufficient in each case. The pO(2) over the cortex correlated well with arterial PO2. Measurements over arteries showed a correlation coefficient of 0.72 (P < 0.001), over veins 0.58 (P < 0.001), over cortical parenchyma 0.46 (P < 0.001), and in a larger region of interest containing vessels and cortical tissue 0.59 (P < 0.001). The frequency of the measurements was 7 Hz with a single measurement covering an area of 30 x 30 mu m. Conclusions: For the first time, nearly online pO(2) maps of a brain cortex can be generated, allowing simultaneously also separate measurements over distinct anatomic structures yielding a good spatial resolution.

Item Type: Article
Uncontrolled Keywords: TRAUMATIC BRAIN-INJURY; SEVERE HEAD-INJURY; EPR OXIMETRY; TISSUE; TENSION; CORTEX; PH; CAPILLARIES; ARTERIOLES; HYPEROXIA; brain; oxygenation; p(ti)iO(2); partial pressure; time-resolved luminescence imaging
Subjects: 600 Technology > 610 Medical sciences Medicine
Divisions: Medicine > Lehrstuhl für Neurochirurgie
Depositing User: Dr. Gernot Deinzer
Date Deposited: 05 Nov 2020 06:35
Last Modified: 05 Nov 2020 06:35
URI: https://pred.uni-regensburg.de/id/eprint/31120

Actions (login required)

View Item View Item