Moritz, Stefan and Kasprzak, Piotr and Woertgen, Chris and Taeger, Kai and Metz, Christoph (2008) The accuracy of jugular bulb venous monitoring in detecting cerebral ischemia in awake patients undergoing carotid endarterectomy. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 20 (1). pp. 8-14. ISSN 0898-4921,
Full text not available from this repository. (Request a copy)Abstract
To investigate the accuracy of jugular bulb venous monitoring in detecting cerebral ischemia, we performed ipsilateral jugular bulb venous monitoring in 48 patients undergoing carotid surgery under regional anesthesia. Cerebral ischemia was assumed when neurologic deterioration occurred. During carotid clamping, the maximal arterial-jugular venous oxygen content difference [AJDO(2) (max)], the minimal jugular venous oxygen saturation [SjO(2) (min)], the maximal arterial-jugular venous lactate content difference [AJDL (max)], the maximal lactate oxygen index [LOI (max)], and the maximal modified LOI [mLOI (niax)] were determined. To quantify the selectivity of each parameter, we performed receiver operating characteristic analysis and determined the area under the curve. The cutoff points providing the highest accuracy and the corresponding sensitivity (Se) and specificity (Spec) were determined. Neurologic deterioration occurred in 12 patients. All parameters, except AJDO(2) (max), showed significant ability to distinguish between ischemic and nonischemic patients. The area under the curve for AJDL (max) was 0.840, for SjO(2) (min) 0.766, for LOI 0.745, for mLOI 0.748, and for AJDO(2) (max) 0.672. We found cutoff points of >= 0. 16 mmol/L for AJDL (max) (Se = 67%; Spec = 86%) and <= 55% for SjO(2) (Se = 75%; Spec = 83%). In conclusion, the present investigation shows that AJDL, SjO(2), LOI, and mLOI provide the ability to detect cerebral hypoperfusion. The highest accuracy was found for AJDL. Neither the calculation of LOI nor of mLOI showed improved results.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | SEVERE HEAD-INJURY; OXYGEN-SATURATION; BRAIN INJURY; BLOOD-FLOW; METABOLISM; LACTATE; DIFFERENCE; FLUID; cerebral ischemia; jugular bulb venous monitoring; lactate |
Subjects: | 600 Technology > 610 Medical sciences Medicine |
Divisions: | Medicine > Lehrstuhl für Anästhesiologie Medicine > Abteilung für Gefäßchirurgie Medicine > Lehrstuhl für Neurochirurgie |
Depositing User: | Dr. Gernot Deinzer |
Date Deposited: | 18 Nov 2020 08:01 |
Last Modified: | 18 Nov 2020 08:01 |
URI: | https://pred.uni-regensburg.de/id/eprint/31691 |
Actions (login required)
![]() |
View Item |