Screening for carotid injury in trauma patients: Image quality of 16-detector-row computed tomography angiography

Borisch, I. and Boehme, T. and Butz, B. and Hamer, O. W. and Feuerbach, S. and Zorger, N. (2007) Screening for carotid injury in trauma patients: Image quality of 16-detector-row computed tomography angiography. ACTA RADIOLOGICA, 48 (7). pp. 798-805. ISSN 0284-1851, 1600-0455

Full text not available from this repository. (Request a copy)

Abstract

Background: The introduction of multidetector- row computed tomography ( MDCT) has revolutionized the initial management of multiply injured patients. This technology has the potential to improve the imaging of traumatic vascular injuries. Purpose: To evaluate the quality of multidetector- row computed tomography angiography ( MDCTA) of the carotid arteries in the setting of a routine whole- body trauma scan. Material and Methods: 87 trauma patients underwent a routine whole- body CT scan in a 16- detector- row scanner including an MDCTA with a reconstructed axial slice thickness of 3 mm. Images were reviewed by three experienced radiologists with emphasis on image quality. Contrast density, severity, and origin of artifacts and the occurrence of vessel lesions were assessed for different vessel segments. Results: 3642 separate vessel segments were evaluated. Contrast density was rated good or sufficient for diagnosis in 99.8%. A total of 67.3% of vessel segments were free of artifacts, while 27.9% of vessel segments showed minor artifacts not impairing diagnostic evaluation. Clinically relevant artifacts obscuring a vessel segment occurred in 4.7% and were mostly caused by dental hardware. Four dissections of the internal carotid artery were diagnosed by all three radiologists. Conclusion: As a rapid screening test for blunt carotid artery injury, integration of MDCTA in the routine imaging workup of trauma patients utilizing a whole- body CT trauma scan is possible and practicable. Image quality is mostly sufficient for diagnosis, but impaired in a few cases by artifacts deriving primarily from dental hardware.

Item Type: Article
Uncontrolled Keywords: BLUNT CEREBROVASCULAR INJURIES; MASK BONE ELIMINATION; CT ANGIOGRAPHY; ARTERY INJURIES; DISSECTION; DIAGNOSIS; NECK; RECONSTRUCTION; ACCURACY; OUTCOMES; artifacts; carotid artery; dissection; multidetector computed tomography; trauma
Subjects: 600 Technology > 610 Medical sciences Medicine
Divisions: Medicine > Lehrstuhl für Röntgendiagnostik
Depositing User: Dr. Gernot Deinzer
Date Deposited: 23 Dec 2020 11:41
Last Modified: 23 Dec 2020 11:41
URI: https://pred.uni-regensburg.de/id/eprint/33307

Actions (login required)

View Item View Item