Perlick, Lars and Tingart, Markus and Wiech, Oliver and Beckmann, J. and Bathis, Holger (2005) Computer-assisted cannulated screw fixation for slipped capital femoral epiphysis. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 25 (2). pp. 167-170. ISSN 0271-6798,
Full text not available from this repository. (Request a copy)Abstract
In slipped capital femoral epiphysis (SCFE), cannulated screw fixation is a standard procedure. The aim of this study was to investigate the feasibility of a fluoroscopy-supported navigation system for screw fixation in SCFE. Using a fluoroscopy-enhanced navigation system, a cannulated screw fixation was performed in seven hips of four patients. The navigation system showed a high feasibility in instrument visualization and implant placing. The mean x-ray time was 6.2 seconds. Initial experiences are very promising and show advantages of the fluoroscopy-supported navigation. Considerably reduced x-ray exposure for patients and surgeons is possible. In the future, further efforts will be necessary to develop navigation-specific instruments to enhance the precision of screw positioning.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | PIN PLACEMENT; SINGLE SCREW; NAVIGATION; SYSTEM; INSITU; slipped capital femoral epiphysis; cannulated screw fixation; navigation system; radiation exposure |
| Subjects: | 600 Technology > 610 Medical sciences Medicine |
| Divisions: | Medicine > Lehrstuhl für Orthopädie |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 21 May 2021 11:04 |
| Last Modified: | 21 May 2021 11:04 |
| URI: | https://pred.uni-regensburg.de/id/eprint/36431 |
Actions (login required)
![]() |
View Item |

