Held, P. and Fruend, R. and Seitz, Johannes and Nitz, W. and Haffke, T. and Hees, H. and Waldeck, A. (2000) Comparison of a T2*W. 3D CISS and a T2 W. 3D turbo spin echo sequence for the anatomical study of facial and vestibulocochlear nerves. JOURNAL OF NEURORADIOLOGY, 27 (3). pp. 173-178. ISSN 0150-9861
Full text not available from this repository.Abstract
Thirty healthy volunteers were examined with a T2* w. 3D CISS and a T2 w. 3D turbo spin echo (TSE) sequence in order to compare the facial and vestibulocochlear nerve detectability in the cerebellopontine angle and the internal auditory canal. CISS was significantly better than 3D TSE for nerve detectability in the cerebellopontine angle and equally as good as 3D TSE in the internal auditory canal. We would therefore recommend the inclusion of CISS in an MR imaging protocol of the facial and vestibulocochlear nerves.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | INNER-EAR; CEREBELLOPONTINE ANGLE; TEMPORAL BONE; MR; Magnetic Resonance Imaging; MRI; 3D turbo spin echo sequence; 3D gradient echo sequence; facial nerve; vestibulocochlear nerve; anatomy |
Subjects: | 500 Science > 570 Life sciences 600 Technology > 610 Medical sciences Medicine |
Divisions: | Medicine > Lehrstuhl für Hals-Nasen-Ohren-Heilkunde Medicine > Lehrstuhl für Röntgendiagnostik Biology, Preclinical Medicine > Institut für Anatomie |
Depositing User: | Dr. Gernot Deinzer |
Date Deposited: | 28 Mar 2022 14:21 |
Last Modified: | 28 Mar 2022 14:21 |
URI: | https://pred.uni-regensburg.de/id/eprint/42248 |
Actions (login required)
![]() |
View Item |