Pinless Navigation in Unicompartmental Knee Arthroplasty

Keuntje-Perka, Sarah and von Roth, Philipp and Worlicek, Michael and Koch, Matthias and Alt, Volker and Kaiser, Moritz (2021) Pinless Navigation in Unicompartmental Knee Arthroplasty. JOURNAL OF CLINICAL MEDICINE, 10 (11): 2422. ISSN , 2077-0383

Full text not available from this repository. (Request a copy)

Abstract

Purpose: In contrast to total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA) is a true resurfacing procedure, as none of the ligaments are replaced or released, and the pre-arthritic leg alignment is the major goal. As such, the alignment of the tibial component plays a crucial role in postoperative knee function and long-term survival. Pinless navigation has shown reliable results in total knee arthroplasty. To the best of our knowledge, the use of pinless navigation has not been investigated for UKA. Therefore, the present study investigated whether implantation of the tibial component in 3 degrees varus, which is closer to the anatomical axis, is feasible with a pinless optical navigation system. Methods: 60 patients with the diagnosis of an unicompartmental arthritis, were eligible for UKA and treated with implantation in 3 degrees varus alignment of the tibial component. Two groups were established. In the treatment group the tibial component was aligned using a pinless navigation technique. In the control group, a conventional extramedullary alignment guide was used. A clinical and radiographic follow up took place within 1 year of operation. Results: 57 Patients were eligible for analysis. No clinical incidents were noted in the follow up period. The desired target value, the position of the tibial component, was accurately achieved with an average of 3 degrees medial inclination using the pinless navigation as well as using the conventional technique. Mean incision to suture time was negligible between the two techniques. The mean suture time was 43.2 min with pinless navigation and 42.7 min with the conventional technique. Conclusions: With pinless navigation in UKA, a method was presented that made it possible to achieve sled prosthesis alignment at the level of a high-volume surgeon. These results were achieved with an irrelevant increase of surgical time and without placement of pins.

Item Type: Article
Uncontrolled Keywords: ALIGNMENT; OUTCOMES; knee arthroplasty; unicompartmental; navigation; pinless
Subjects: 600 Technology > 610 Medical sciences Medicine
Divisions: Medicine > Lehrstuhl für Unfallchirurgie
Depositing User: Dr. Gernot Deinzer
Date Deposited: 23 Aug 2022 12:22
Last Modified: 23 Aug 2022 12:22
URI: https://pred.uni-regensburg.de/id/eprint/46342

Actions (login required)

View Item View Item