Blandino Ortiz, Aaron and Belliato, Mirko and Broman, Lars Mikael and Lheureux, Olivier and Malfertheiner, Maximilian Valentin and Xini, Angela and Pappalardo, Federico and Taccone, Fabio Silvio (2021) Early Findings after Implementation of Veno-Arteriovenous ECMO: A Multicenter European Experience. MEMBRANES, 11 (2): 81. ISSN , 2077-0375
Full text not available from this repository. (Request a copy)Abstract
Extracorporeal membrane oxygenation (ECMO) is increasingly used to treat cardiopulmonary failure in critically ill patients. Peripheral cannulation may be complicated by a persistent low cardiac output in case of veno-venous cannulation (VV-ECMO) or by differential hypoxia (e.g., lower PaO2 in the upper than in the lower body) in case of veno-arterial cannulation (VA-ECMO) and severe impairment of pulmonary function associated with cardiac recovery. The treatment of such complications remains challenging. We report the early effects of the use of veno-arterial-venous (V-AV) ECMO in this setting. Methods: Retrospective analysis including patients from five different European ECMO centers (January 2013 to December 2016) who required V-AV ECMO. We collected demographic data as well as comorbidities and ECMO characteristics, hemodynamics, and arterial blood gas values before and immediately after (i.e., within 2 h) V-AV implementation. Results: A total of 32 patients (age 53 (interquartiles, IQRs: 31-59) years) were identified: 16 were initially supported with VA-ECMO and 16 with VV-ECMO. The median time to V-AV conversion was 2 (1-5) days. After V-AV implantation, heart rate and norepinephrine dose significantly decreased, while PaO2 and SaO(2) significantly increased compared to baseline values. Lactate levels significantly decreased from 3.9 (2.3-7.1) to 2.8 (1.4-4.4) mmol/L (p = 0.048). A significant increase in the overall ECMO blood flow (from 4.5 (3.8-5.0) to 4.9 (4.3-5.9) L/min; p < 0.01) was observed, with 3.0 (2.5-3.2) L/min for the arterial and 2.8 (2.1-3.6) L/min for the venous return flows. Conclusions: In ECMO patients with differential hypoxia or persistently low cardiac output syndrome, V-AV conversion was associated with improvement in some hemodynamic and respiratory parameters. A significant increase in the overall ECMO blood flow was also observed, with similar flow distributed into the arterial and venous return cannulas.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | ; ECMO; veno-artero-venous; differential hypoxia; low cardiac output |
| Subjects: | 600 Technology > 610 Medical sciences Medicine |
| Divisions: | Medicine > Lehrstuhl für Innere Medizin II |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 21 Sep 2022 08:34 |
| Last Modified: | 21 Sep 2022 08:34 |
| URI: | https://pred.uni-regensburg.de/id/eprint/47804 |
Actions (login required)
![]() |
View Item |

