Kaiser, Ulrich and Kaltenhauser, Simone and Kaiser, Florian and Vehling-Kaiser, Ursula and Herr, Wolfgang and Stroszczynski, Christian and Becker, Claus and Dropco, Ivor and Jung, Ernst Michael (2024) Use of a handheld system for interventional ultrasound with puncture and biopsy in an in vitro liver model. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 88 (s1). S45-S56. ISSN 1386-0291, 1875-8622
Full text not available from this repository. (Request a copy)Abstract
BACKGROUND AND OBJECTIVE: Ultrasound-guided interventions (such as biopsies) of unclear lesions are indicated if microcirculatory changes indicate possible malignant lesions. These place high demands on the ultrasound device used. In order to potentially reduce the often associated high technical effort, the wireless ultrasound device Vscan AirTM was examined as a possible ultrasound device for the intervention biopsy. METHODS: As part of an advanced training course on Computertomographie- and ultrasound-guided biopsy and ablation procedures, participants were asked about the image quality of the handheld device used by means of questionnaires. Various lesions were evaluated at a depth of 1.0 to 5.0 cm in an in vitro liver model. The image quality was evaluated independently before, during and after the intervention. The rating scale contained values from 0 (no assessment possible) to 5 (maximum RESULTS: A total of 11 participants took part in the study (n = 4 male [36.4%], n = 7 female [63.6%]). A total of five tumor like lesions at different depths (1 cm, 2 cm, 3 cm, 4 cm, >4 cm) were assessed separately. In all cases, an adequate biopsy of the target lesion (1 cm in length, core filling 5 mm) was successful. From a depth of 3 cm, the image quality of the mobile device increasingly decreased, but the image quality of the high-end system was still not impaired. Compared to the high-end device, there was a highly significant difference in image quality from a depth of 3 cm (p < 0.01). Assessment by inexperienced examiners using a handheld device was adequately possible. CONCLUSIONS: Mobile interventional ultrasound represents a potential alternative for the biopsy of unclear tumorous lesions with microcirculatory disorders with limited depth localization.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Ultrasound; mobile ultrasound; high end ultrasound; in vitro model; tumor diagnostics; ultrasound interventions |
| Subjects: | 600 Technology > 610 Medical sciences Medicine |
| Divisions: | Medicine > Lehrstuhl für Chirurgie Medicine > Lehrstuhl für Innere Medizin III (Hämatologie und Internistische Onkologie) Medicine > Lehrstuhl für Röntgendiagnostik |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 16 Oct 2025 05:15 |
| Last Modified: | 16 Oct 2025 05:15 |
| URI: | https://pred.uni-regensburg.de/id/eprint/63717 |
Actions (login required)
![]() |
View Item |

