Szymski, Dominik and Walter, Nike and Straub, Josina and Wu, Yinan and Melsheimer, Oliver and Grimberg, Alexander and Alt, Volker and Steinbrueck, Arnd and Rupp, Markus (2024) Low implantation volume, comorbidities, male sex and implantation of constrained TKA identified as risk factors for septic revision in knee arthroplasty: A register-based study from the German Arthroplasty Registry. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 32 (7). pp. 1743-1752. ISSN 0942-2056, 1433-7347
Full text not available from this repository. (Request a copy)Abstract
Purpose: Periprosthetic joint infection (PJI) is a major cause of revision surgery after total knee arthroplasty (TKA) and unicondylar knee arthroplasty (UKA). Patient- and hospital-related risk factors need to be assessed to prevent PJI. This study identifies influential factors and differences in infection rates between different implant types. Methods: Data were obtained from the German Arthroplasty Registry. Septic revisions were calculated using Kaplan-Meier estimates with septic revision surgery as the primary endpoint. Patients with constrained and unconstrained TKA or UKA were analysed using Holm's multiple log-rank test and Cox's proportional hazards ratio. The 300,998 cases of knee arthroplasty analysed included 254,144 (84.4%) unconstrained TKA, 9993 (3.3%) constrained TKA and 36,861 (12.3%) UKA with a maximum follow-up of 7 years. Results: At 1 year, the PJI rate was 0.5% for UKA and 2.8% for TKA, whereas at 7 years, the PJI rate was 4.5% for UKA and 0.9% for TKA (p < 0.0001). The PJI rate significantly increased for constrained TKA compared to unconstrained TKA (p < 0.0001). The PJI rate was 2.0% for constrained TKA and 0.8% for unconstrained TKA at 1 year and 3.1% and 1.4% at 7 years. Implantation of a constrained TKA (hazard ratio [HR] = 2.55), male sex (HR = 1.84), increased Elixhauser score (HR = 1.18-1.56) and implant volume of less than 25 UKA per year (HR = 2.15) were identified as risk factors for revision surgery; an Elixhauser score of 0 (HR = 0.80) was found to be a preventive factor. Conclusions: Reduced implant volume and constrained knee arthroplasty are associated with a higher risk of PJI. Comorbidities (elevated Elixhauser score), male sex and low UKA implant volume have been identified as risk factors for PJI. Patients who meet these criteria require specific measures to prevent infection. Further research is required on the potential impact of prevention and risk factor modification. Level of Evidence: Level III.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | PERIPROSTHETIC JOINT INFECTION; HEMIARTHROPLASTY; CEMENT; cemented; constrained; infection; knee; revision; unconstrained |
| Subjects: | 600 Technology > 610 Medical sciences Medicine |
| Divisions: | Medicine > Lehrstuhl für Unfallchirurgie |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 14 Jan 2026 07:22 |
| Last Modified: | 14 Jan 2026 07:22 |
| URI: | https://pred.uni-regensburg.de/id/eprint/64177 |
Actions (login required)
![]() |
View Item |

