Veltmann, Christian and Duncker, David and Doering, Michael and Gummadi, Siva and Robertson, Michael and Wittlinger, Thomas and Colley, Byron J. and Perings, Christian and Jonsson, Orvar and Bauersachs, Johann and Sanchez, Robert and Maier, Lars S. (2024) Therapy duration and improvement of ventricular function in de novo heart failure: the Heart Failure Optimization study. EUROPEAN HEART JOURNAL, 45 (30). pp. 2771-2781. ISSN 0195-668X, 1522-9645
Full text not available from this repository. (Request a copy)Abstract
Background and Aims In patients with de novo heart failure with reduced ejection fraction (HFrEF), improvement of left ventricular ejection fraction (LVEF) is expected to occur when started on guideline-recommended medical therapy. However, improvement may not be completed within 90 days. Methods Patients with HFrEF and LVEF <= 35% prescribed a wearable cardioverter-defibrillator between 2017 and 2022 from 68 sites were enrolled, starting with a registry phase for 3 months and followed by a study phase up to 1 year. The primary endpoints were LVEF improvement > 35% between Days 90 and 180 following guideline-recommended medical therapy initiation and the percentage of target dose reached at Days 90 and 180. Results A total of 598 patients with de novo HFrEF [59 years (interquartile range 51-68), 27% female] entered the study phase. During the first 180 days, a significant increase in dosage of beta-blockers, renin-angiotensin system inhibitors, and mineralocorticoid receptor antagonists was observed (P < .001). At Day 90, 46% [95% confidence interval (CI) 41%-50%] of study phase patients had LVEF improvement > 35%; 46% (95% CI 40%-52%) of those with persistently low LVEF at Day 90 had LVEF improvement > 35% by Day 180, increasing the total rate of improvement > 35% to 68% (95% CI 63%-72%). In 392 patients followed for 360 days, improvement > 35% was observed in 77% (95% CI 72%-81%) of the patients. Until Day 90, sustained ventricular tachyarrhythmias were observed in 24 wearable cardioverter-defibrillator carriers (1.8%). After 90 days, no sustained ventricular tachyarrhythmia occurred in wearable cardioverter-defibrillator carriers. Conclusions Continuous optimization of guideline-recommended medical therapy for at least 180 days in HFrEF is associated with additional LVEF improvement > 35%, allowing for better decision-making regarding preventive implantable cardioverter-defibrillator therapy.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | WEARABLE CARDIOVERTER-DEFIBRILLATOR; EJECTION FRACTION; RISK; DEATH; Heart failure; Wearable cardioverter-defibrillator; Guideline-recommended medical therapy |
| Subjects: | 600 Technology > 610 Medical sciences Medicine |
| Divisions: | Medicine > Lehrstuhl für Innere Medizin II |
| Depositing User: | Dr. Gernot Deinzer |
| Date Deposited: | 22 Jan 2026 09:28 |
| Last Modified: | 22 Jan 2026 09:28 |
| URI: | https://pred.uni-regensburg.de/id/eprint/65300 |
Actions (login required)
![]() |
View Item |

